SENKO SN-EN-08 Instruction Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
SENKO cookers C-25, C-35 and C-30P Instruction manual 36
5.7. FUEL BOX
Fuel box (15) is mounted on the guide bars.
Maximum bearing capacity of the box is 15
kg. The box is removed as follows :
pull the box towards yourself all the way,
lift the box upwards for approx. 5 mm and
lightly pull towards yourself,
the box is mounted back by reversing the procedure!
Easily flammable or explosive objects must not be stored in the box!
6. CLEANING
6.1. CLEANING THE COOKER
The cooker and the chimney must be regularly cleaned (at least once
a month).
The ash box (14) and the box area must be cleaned on daily basis. Ash
disposal is to be executed in environmentally acceptable manner and in
accordance with safety procedures.
The glass (28) on the upper firebox door (8) should be cleaned as
necessary using the soot and grease cleaning agent (26).
The agent is delivered with the cooker !
The oven (9) should be cleaned after every instance of use.
While cleaning the top side of the cooker (figure 25), it is necessary to
remove the cooking plate (1) and thoroughly clean the soot from the boiler,
around the oven and flue gas deflector, including the chimney outlet
opening (16).
Cooker cleaning is to be performed only when the cooker is
inactive and when it is cold !
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 51 52

Comments to this Manuals

No comments