Sensor Detecting
range
Resolution
Oxygen(O2) 0~30% vol. 0.1% vol.
Installation Drawing
Carbon
Monoxide(CO)
0~1000ppm 1ppm
Hydrogen
Sulfide(H2S)
0~200ppm 1ppm
Methane(CH4) 0~100%LEL 1% LEL
Hydrogen(H2) 0~1,000ppm 1ppm
Ammonia(NH3) 0~100ppm 1ppm
Detector
Size 150m(W) x 165mm(H) x110 mm(D)
Wei
ht 1.8k
Calibration Two-point calibration
Accuracy
≤ ±5% (Full Scale)
Response Time ≤ 30 sec. (T
90
)
IP Rating IP65
Ex
losion
roof EX d IIC T5
LCD display
Power 10~30V DC, max 60mA at 24V
Output 4~20mA, RS485 Modbus RTU
(Baud rate of 4800, 9600, 19200)
Sampling Internal diffusion
Operating
-20˚C ~ 50˚C RH
① Gas type
② Unit
③ Gas concentration
-
Dry contacts Max 30V, 5A.
One for Low and Fault alarm,
Another for High alarm
Terminal BR-500C(8pins), AWG24
Mounting 2 holes ¾” NPT
Specification